Transpiration

Middle schoolBiologySteady illustrative transpiration conductance with capillary-area potometer measurements

Drag the capillary bubble to inspect a measured displacement. Click the leaf to close its stomata, click the fan control or drag the humidity handle, then run a fresh uptake trial.

3D

Drag the apparatus to adjust it. Drag the background to rotate. Scroll to zoom.

Measurement notebook

Change the setup, test a prediction and save the result. Up to 12 snapshots are kept.

About this experiment

Use a virtual potometer to measure water uptake from the travel of an air-bubble marker. Change humidity, wind, light, leaf area and capillary radius, then compare displacement with the actual water volume.

Learning goals

  • Convert bubble travel into water volume using capillary cross-section.
  • Relate transpiration to vapour-pressure deficit and stomatal opening.
  • Distinguish a larger instrument displacement from a larger biological uptake.

How to use it

  1. 1Run a trial and record bubble displacement, elapsed time and uptake.
  2. 2Double the capillary radius without changing leaf conditions and compare travel.
  3. 3Close the stomata or set humidity to saturation and repeat.
  4. 4Shade the leaf and compare uptake over equal observation times.

The model

Convert the measured capillary displacement into water volume.
The model conductance includes the specified light, wind and pore factors.

Assumptions

  • A specified conductance scales with leaf area, pore opening, light and wind. Vapour-pressure deficit uses saturation pressure at the selected leaf and air temperature.
  • Uptake is treated as equal to transpiration. Growth, tissue storage, leaks, xylem damage and differences between leaf and air temperature are omitted.
  • The capillary has a uniform circular bore. One mL is 1000 cubic mm, so bubble displacement is volume divided by cross-section.
  • The run stops when its 200 mm scale ends, or at 60 minutes. Environmental changes start a new constant-condition trial.
  • Dragging the bubble selects the model time corresponding to its position; it does not force water through a living leaf.

Try this in class

  1. Q1Why does a narrower capillary make uptake easier to detect?
  2. Q2Why does wind have little effect when humidity is saturated?

Frequently asked questions

Does moving the bubble change the transpiration rate?

No. It selects a measurement time. The environmental controls determine the model rate.

Does a potometer directly measure water lost from the leaf?

It measures water uptake. This teaching model assumes that uptake matches transpiration over the trial.